Sensor Calibration

This section includes:

Sensor calibration, also known as black shading, is a process during which the camera optimizes image quality by ensuring that pixel sensitivity remains consistent throughout the sensor. Calibrating the sensor generates a calibration map based on system and environment settings. After calibration, the sensor shows a uniform noise profile over the whole area without any falloffs on any side.

For more information, see the Sensor Calibration Methods article.

NOTE: Calibration maps are still available after performing a system restore.

Check Noise Profile

To check the current noise profile, follow the instructions below:

  1. Ensure that the camera reaches the temperature you want to use for your shoot.
  2. Set the exposure to the exposure you want to use for your shoot.
  3. Put a lens cap on the lens (if a lens is attached) or a front body cap on the camera (if a lens is not attached).
  4. Set FLUT to 8.000. For more information, go to FLUT.
  5. Check the noise that displays on the monitor:
    • The noise is random, with no fixed patterns or lines. The sensor is calibrated.
    • The noise has patterns or lines. Calibrate the sensor. For more information, go to Calibration Capture (Sensor Calibration).

When to Calibrate Sensor

Calibration is required:

  • After an extreme change in temperature (+/– 30°F or +/–15°C) from the current calibration map.
  • After an extreme change in exposure time (+/– 1/2 sec) from the current calibration map.
  • If either the T or E in the CAL: T/E indicator is not green.
  • For EPIC DRAGON or SCARLET DRAGON: After each firmware upgrade.
  • For EPIC MYSTERIUM-X or SCARLET MYSTERIUM-X: After a firmware upgrade if instructed to do so in the firmware release notes.

To check the temperature/exposure of the current calibration file, go to Menu > Settings > Maintenance > System Status > Project Status.

EPIC/SCARLET Operation Guide
955-0156_V6.3, REV-N
Copyright © 2019 RED.COM, LLC. All rights reserved.